Front loading lifting tower.
The WTS Series means a change of concept within the front load towers, as it introduces the new Structural Mode. This Structural Mode does not use the winch to lift the load, but involves lifting the load with the help of a manual or electric hoist. That is, the tower is used as a structure that is all locked to the required working height. Once the tower is raised to this desired height, the load must be raised with the hoist. The Structural Mode performs improved loading capactities.
Furthermore, the WTS Series incorporates the innovative Dynamic Overlap system.
Dynamic Overlap is an innovative solution that increases the resistance of the towers and reduces their deflection, making that each tower section overlaps with the previous one at different distances, as with trees in nature. This means that all efforts are concentrated in the same way in all the sections of the tower. Thanks to this, the tower can withstand greater efforts with less deflection.
Features
- Mechanism mode and structural mode.
- 4 extensible sections made of extruded aluminum.
- Front and rear bars for additional reinforcement.
- Wheels at the base of the tower.
Material | Aluminum and iron |
Folded Height | 1.60 m / 5.25 ft |
Unfolded base | 0.56 x 0.44 / 1.84 x 1.44 ft |
Maximum height | 5.07 m / 16.63 ft |
Minimum carriage height | 0.60 m / 1.96 ft |
Unfolded base diameter | 2.65 m / 8.69 |
Distance between front legs | 1.88 m / 6.17 ft |
Distance between hind legs | 1.60 m / 5.25 ft |
Brackets length | 0.50 m / 1.64 ft |
No. of sections | 4 |
Minimum Load | 25 Kg / 55.12 Lb |
Max load (structure mode) | 380 Kg / 831.76 Lb |
Max load (mechanism mode) | 350 Kg / 771.62 Lb |
Net Weight | 110.20 Kg / 242.84 Lb |
Winch | 900 Kg / 1984 Lb |
Cable diameter | 6 mm² |
Noise Emission | 70 dB |
Compatible accessories | AWS 403, AWS 302, AWS 401 |
- The new Regulation. DIN56950, DGUV17/18
The new standard DIN 56950 especifies the lifters safety rules in its parts 1 and 3. It is the base of the new regulations DGUV17/18 replacing the old BGVC1 which is obsolete. WORK PRO LIFTERS is the first brand which has introduced a range of lifters compliant with this new regulation. The biggest limitations established by the new DIN56950
1 The 5º test
All lifters must be tested with its maximum load and 5 degrees ground inclination. All WTS series has passed this test thanks to the DYNAMIC OVERLAP PATENT that reduces the deflection of the profiles and makes the lifter much stronger.
2 Automatic load limiter system
All Lifters must have a built-in system that detects overload and limits the lifting process. All WTS lifters can be suppplied with the new DYNSYS limitation system which automatically blocks and limits the lifting when the load is overpassed.
3 Maximum PAR 15Kg in the handle
The maximum PAR that an operator must apply to the handle cannot exceed 15kg. This is also solved with DYNSYS